Fixes are available
APAR status
Closed as program error.
Error description
Compilation errors are observed in generated COBOL for Form groups where the name of the form contains a special character like an underscore. Example error which could indicate this problem: IGYPA3007-S "EZEHANDLE-DVPFMXTE" was not defined as a procedure-name. The statement was discarded.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * A compile error can occur if a print form name contains a * * special character (such as underscore) in the first 8 * * positions of the name. * **************************************************************** * PROBLEM DESCRIPTION: * * The compile error would be something similar to IGYPA3007-S * * "EZEHANDLE-????????" was not defined as a procedure-name, * * where ???????? is the name of the print form (with X in the * * position of the special character). * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The user can work around this problem by not using special characters in the form name, or by using the alias = "aliasName" annotation for the form, or by applying the fixtest and regenerating the form.
Temporary fix
Comments
APAR Information
APAR number
PI36351
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
911
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-05
Closed date
2016-04-05
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]