A fix is available
APAR status
Closed as program error.
Error description
On some Linux machine, Tomcat failed to start when MobileFirst runtime is deployed. The problem is on certain Linux, the HTTP protocol is not available when Tomcat started. And with the latest Apache HTTP client 4.3, there is no socket timeout hence Tomcat is waiting infinitely.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Mobile First Platform running on Tomcat * **************************************************************** * PROBLEM DESCRIPTION: * * When defining a MobileFirst Platform runtime in a Tomcat * * server, the server hangs during the startup and never starts * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
When the runtime starts it needs to send a http ping request to check that the admin services is available. If the admin services is not available, the runtime retries every 2s the ping request during 2 mns. After 2 mns if still not successful an exception is emitted by the runtime. When the first http ping request is sent Tomcat can have not yet initialized the http protocol. As the default timeout is infinite, the http request never returns, the thread is waiting infinitely and so Tomcat is blocked since the Tomcat startup is done in sequence and not in parallel. The fix sets a timeout of 2 seconds. So if the http protocol is not available, there is a timeout error after 2s handled by the runtime that will retry every 2s during 2 mns. So the thread is no more blocked and Tomcat can continue to start the server. When the http protocol is initialized the next ping will succeed.
Temporary fix
Comments
APAR Information
APAR number
PI36182
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-03-03
Closed date
2015-03-06
Last modified date
2015-03-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R630 PSY
UP