A fix is available
APAR status
Closed as program error.
Error description
An ifix was applied to the Worklight environment and Android apps that are built at the new level are no longer able to connect to the Worklight server. When the app is reverted to the previous version, the problem does not occur. The error that is received is the following: ---------- Unknown chromium error: 0 Host is not responsive. Try to manuall access the URL through the android emulator browser to verify the connectivity. ---------- When the URL is accessed through the browser, the error does not occur.
Local fix
In the Cordova config.xml file, the following will be found: <access origin=".*"/> This should be changed to the following to resolve the issue: <access origin="*"/>
Problem summary
**************************************************************** * USERS AFFECTED: * * Developers building Android applications. * **************************************************************** * PROBLEM DESCRIPTION: * * The config.xml template for the Android whitelist contains * * the value ".*", where it should be "*" (without the leading * * dot). This was tolerated in earlier versions of Cordova, * * but that toleration was eliminated after addressing a * * security vulnerability. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The template was fixed to correct the value and the Knowledge Center was updated with additional information.
Temporary fix
Comments
APAR Information
APAR number
PI24294
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-08-20
Closed date
2014-12-19
Last modified date
2014-12-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R600 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 October 2021