Fixes are available
APAR status
Closed as program error.
Error description
Uploading an application or an adapter to the Worklight Console through Multi-Protocol Gateway in DataPower may fail. On the server side, the following stack trace is emitted in the application server log: ServletWrappe E com.ibm.ws.webcontainer.servlet.ServletWrapper service SRVE0068E: An exception was thrown by one of the service methods of the servlet [ManagementServlet] in application [Worklight_Administration_Service_DP63]. Exception created : [java.lang.StringIndexOutOfBoundsException at java.lang.String.substring(String.java:1150) at org.apache.wink.common.internal.providers.multipart.MultiPartPar ser.parseHeaders(MultiPartParser.java:270) The problem is triggered by MPG adding double quotation marks to the MIME multipart message's boundary in the Content-type header. For example, this header multipart/form-data; boundary=---------------------------2925426766838 becomes multipart/form-data; boundary="---------------------------2925426766838"
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Worklight console users that have the rights to upload * * applications and adapters * **************************************************************** * PROBLEM DESCRIPTION: * * Uploading applications or adapters with the Worklight * * Console when using the Datapower Multi Protocol Gateway * * fails with a StringIndexOutOfBoundsException. * **************************************************************** * RECOMMENDATION: * * NONE * ****************************************************************
Problem conclusion
Problem arises because Datapower MPG encloses the boundary of the multipart form data in the HTTP Content header between double quotes that is not supported by Wink.
Temporary fix
Comments
APAR Information
APAR number
PI31269
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-10
Closed date
2015-01-13
Last modified date
2015-01-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R620 PSY
UP
R630 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021