Error description
Error Message: Typically, occasional crash in runtime (when some specific data type happens to be unresolved in that JIT-ed method) . Stack Trace: N/A .
Local fix
Problem summary
This can only happen on AIX7.3 running on POWER10, and it only materialized in IBM SDK8 SR6 FP35 and FP36 (since POWER10 was not enabled in prior releases). Using prefixed instruction in unresolved sequence is not expected. that caused runtime crash when it happened.
Problem conclusion
Disable mapping prefixed instruction during codegen when the underlying data is unresolved. . This APAR will be fixed in the following Java Releases: 8 SR7 (8.0.7.0) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ35132
Reported component name
JAVA CLASS LIBS
Reported component ID
620700130
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-09-23
Closed date
2021-09-23
Last modified date
2021-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JAVA CLASS LIBS
Fixed component ID
620700130
Applicable component levels
R800 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
22 February 2022