APAR status
Closed as program error.
Error description
If the sequence number of case events to be processed by the case emitter is in exponential format, the event is not processed and a JAVA.LANG.NUMBERFORMATEXCEPTION is logged in the WebSphere application log SystemOut.log. The following is an example. [7/20/21 19:47:57:173 PDT] 000000f4 IcmOiEmitter E com.ibm.oi.icm.event.emitter.IcmOiEmitter run Exception during processinggg java.lang.NumberFormatException: For input string: "1.0506086" java.lang.NumberFormatException: For input string: "1.0506086" at java.lang.NumberFormatException.forInputString(NumberFormatExcep tion.java:76) at java.lang.Integer.parseInt(Integer.java:592) at java.lang.Integer.parseInt(Integer.java:627) at com.ibm.oi.icm.event.emitter.util.EventLog.<init>(EventLog.java: 86) at com.ibm.oi.icm.event.emitter.DataStore.prepareAllLogs(DataStore. java:185) at com.ibm.oi.icm.event.emitter.IcmOiEmitter.run(IcmOiEmitter.java: 120) at java.util.concurrent.Executors$RunnableAdapter.call(Executors.ja va:522) at java.util.concurrent.FutureTask.runAndReset(FutureTask.java:319) at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFuture Task.access$301(ScheduledThreadPoolExecutor.java:191) at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFuture Task.run(ScheduledThreadPoolExecutor.java:305) at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExec utor.java:1160) at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExe cutor.java:635) at java.lang.Thread.run(Thread.java:822)
Local fix
Problem summary
No additional information is available.
Problem conclusion
A fix is available or will be available that ensures the case emitter can handle the sequence numbers of case events in any format.
Temporary fix
Comments
APAR Information
APAR number
JR63935
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
K00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-07-28
Closed date
2021-09-08
Last modified date
2021-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"20.0.0.1"}]
Document Information
Modified date:
09 September 2021