IBM Support

IJ34793: SIGOPTION NOT BEING EVALUATED CORRECTLY FROM TABLE ROW.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Sigoption works only when condition evaluates first row,
    otherwise you get BMXAA2256E - Field Value is read-only.
    
    STEPS TO REPRODUCE:
    1. Open Expression builder and enter new condition
    Condition: RKCLASS
    Type: EXPRESSION
    Expression: :assetattribute.datatype ='DATE'
    Always Evaluate: Y
    2. Go to Domains and add new ALN domain.
    Domain: RSKDOMALN
    Data Type: UPPER
    Length: 1
    Add Values
    Value: Y Description: Yes
    Value: N Description: No
    3. Go to Application Designer, bring up WOTRACK application
    4. Select Action>Add/Modify Signature Option
    5. New Row
    Sigoption: SIGRSK
    Description: Option for classspecvalue
    Visible: checked
    6. Go to Specification Tab
    7. Add a new Table Column and Textbox for detail per
    Merging classification attribute values into one column
    https://www.ibm.com/docs/en/mamss?topic=controls-merging-classif
    ication-attribute-values-into-one-column
    Label: Value
    Attribute: {CLASSSPECVALUE}
    Advanced Tab>Sigoption: SIGRSK
    8. Configure Conditional Properties dialog
    Sigoption: SIGRSK
    Security Groups: EVERYONE
    Condition for Security Group: RKCLASS
    Condition is True:
    Property: inputmode
    Value: readonly
    9. Go to Classifications
    10. Insert new Classification
    RKCLASSIFICATION
    Usewith: WORKORDER
    2 Attributes:
    -DATERK Data Type =DATE
    -RKNY Domain = RSKDOMALN Data Type =ALN  Save
    11. Insert new Classification
    RKCLASS2
    Usewith: WORKORDER
    2 Attributes:
    -RKNY Domain = RSKDOMALN Data Type =ALN
    -DATERK Data Type =DATE Save
    12. Go to Work Order Tracking and insert new workorder
    13. On Specification tab add RKCLASSIFICATION
    14. In table column click lookup for Value field pick Y and
    save (works)
    15. Insert new workorder
    16. On Specification tab add RKCLASS2
    17. In table column click lookup for Value field pick Y
    You will get the BMXAA2256E - Field Value is read-only.
    
    Results:
    BMXAA2256E - Field Value is read-only.
    
    Expected Results:
    Condition evaluates all records properly without error
    
    Product Version:
    Tivoli's process automation engine 7.6.1.2-IFIX20210504-1949
    Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-31
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo users                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Sig Options were not being evaluated correctly on table      *
    * rows.                                                        *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR will be included in a future Release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ34793

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-01

  • Closed date

    2022-09-13

  • Last modified date

    2022-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
14 September 2022