Substring of system symbol followed by other literals in PROGxx not parsed correctly. For example, if PARMLIB member PROG02 contains an entry with: VOL(TXX&SYSR2(4:1).02)) where symbol &SYSR2 is defined as G2402D, the parsed value is TXX0.0 but it should be TXX002
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of zSecure Collect and users of * * zSecure Admin/Audit exploiting the status * * auditing of security and system * * tables/options reports. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Collect and Audit might * * incorrectly resolve system symbols with * * substring operators specified in PROGxx * * system configuration members. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When system symbols with substring operators are present in PROGxx system configuration members and substring specification is terminated with an optional 'dot' character (like &SYSNAME(1:3).), zSecure Collect and Audit do not handle the 'dot' as part of the system symbol specification hence resolved system symbol value contains the 'dot'.
Problem conclusion
zSecure Collect and Audit have been modified so that they properly handle system symbols substring operators terminated with a 'dot' character.
Temporary fix
Comments
APAR Information
APAR number
OA61908
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-05
Closed date
2021-08-12
Last modified date
2021-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ06259
Modules/Macros
CKARPROG CKFRPROG GKRRPROG
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R240 PSY UJ06259
UP21/08/13 P F108
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"240"}]
Document Information
Modified date:
02 September 2021