A fix is available
APAR status
Closed as program error.
Error description
Although the other intrinsic date functions do honor the setting of the starting date based on the INTDATE(ANSI/LILIAN) compiler option, the INTEGER-OF-FORMATTED-DATE intrinsic function does not honor the INTDATE compiler option. Instead, the Language Reference at https://www.ibm.com/docs/en/cobol-zos/6.3?topic=functions-intege r-formatted-date documents that it always uses the starting date of Jan 1, 1601, i.e. INTDATE(ANSI). This can cause unexpected results if INTDATE(LILIAN) is used. The INTEGER-OF-FORMATTED-DATE intrinsic function is being modified to honor the INTDATE compiler options to bring it in line with the other intrinsic date functions. The Language Reference will be updated as well to reflect this change.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running programs that are compiled with the * * INTDATE(LILIAN) compiler option in effect * * and the program uses the * * INTEGER-OF-FORMATTED-DATE intrinsic * * function. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect result. The return value of * * the INTEGER-OF-FORMATTED-DATE function * * is calculated as if the INTDATE(ANSI) * * compiler option were in effect. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** The INTEGER-OF-FORMATTED-DATE intrinsic function was not properly accounting for the INTDATE(LILIAN) compiler option.
Problem conclusion
The compiler was updated to ensure that it properly takes account of the INTDATE(LILIAN) compiler option when processing the INTEGER-OF-FORMATTED-DATE intrinsic function.
Temporary fix
Comments
APAR Information
APAR number
PH38499
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-28
Closed date
2021-09-27
Last modified date
2021-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI77327
UP21/10/01 P F109
R631 PSY UI77328
UP21/10/01 P F109
R632 PSY UI77329
UP21/10/01 P F109
R63H PSY UI77330
UP21/10/01 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: