IBM Support

PH38340: QUERY MONITOR DOESN'T START WHEN USING VOLUME AS COLLECTOR PARAMETER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Query Monitor doesn't start when using VOLUME as collector
    parameter
    

Local fix

  • Remove the VOLUME statement from the input parameter stream for
    starting the CQM subsystem
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM Db2 Query Monitor for z/OS               *
    *                 users of component:                          *
    *                 - Documentation - Public use                 *
    *                 - CQM Data Collector                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Query Monitor doesn't start when using  *
    *                      VOLUME as collector parameter.          *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    When forming parameters for the dynamic allocation of data sets
    in the program code, the volume name was sent as 8 characters
    instead of 6 characters. In addition, 2 adjacent bytes were
    corrupted.
    

Problem conclusion

  • Fixed program code.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH38340

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-22

  • Closed date

    2021-10-05

  • Last modified date

    2021-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CQM#ALSX CQM#BCMX CQM#CLNR CQM#CQMI CQM#CTLF CQM#DRVX CQM#ERLY
    CQM#GPRF CQM#INIX CQM#INTX CQM#IVCV CQM#IVSM CQM#MSSP CQM#PARM
    CQM#QAPI CQM#QAPX CQM#QSQL CQM#SCLV CQM#SDAQ CQM#SDIR CQM#SSMN
    CQM#STAB CQM#SWTX CQM$CALL CQM$OBJS CQM$QLCA CQM$STMT CQM$ZCMD
    CQM@LSTM CQM@WDB2 CQMBLOB  CQMCPXPT CQMEOSHV CQMISMTS CQMJAR
    CQMMACTX CQMMCALX CQMMCMDX CQMMEACX CQMMEAPX CQMMEARX CQMMEASX
    CQMMEBCX CQMMEBPX CQMMEBRX CQMMEBSX CQMMECCX CQMMECPX CQMMECRX
    CQMMECSX CQMMEMTX CQMMEXCX CQMMEXXX CQMMFREX CQMMFRX1 CQMMINDX
    CQMMMETX CQMMPGEX CQMMQAPX CQMMSACX CQMMSAPX CQMMSARX CQMMSASX
    CQMMSBCX CQMMSBPX CQMMSBRX CQMMSBSX CQMMSCCX CQMMSCPX CQMMSCRX
    CQMMSCSX CQMMSQLX CQMMSRCX CQMMSRVX CQMMVRFX CQMPARSE CQMQSTAT
    CQMTTGEX CQMTTXTX
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R330 PSY UI77449

       UP21/10/09 P F110

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0"}]

Document Information

Modified date:
02 November 2021