IBM Support

IT37257: FAILURE TO PROBE PURESTORAGE X20 DEVICES IN STORAGE INSIGHTS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Users are not able to run a probe on newly added storage array
    ?PureStorage X20? in Storage Insights.
    
    Probe failure messaging visible in GUI is as follows:
    BTADS0102E The probe with the run ID value completed with
    errors.
    HWN021503E The action cannot be completed
    HWNEP0135E External process failed with error code error code .
    HWN025032E Job failed during post processing of collected data
    from the data source
    Internally the details are shown as follows:
    2021-06-06 23:59:12.854 - INFO - HWN021719I Perform collection
    post process tasks for storage system PW-PSX20.
    2021-06-06 23:59:12.855 - ERROR - Error processing data files.
    Exiting...
    2021-06-06 23:59:12.855 - DEBUG - Writing status file...
    2021-06-06 23:59:12.856 - DEBUG - Exit code: 99
    2021-06-06 23:59:12.856 - DEBUG - Traceback (most recent call
    last):
    File ?vsi_thirdparty/MainLauncher.py?, line 357, in run_reporter
    
    File ?Reporter.py?, line 95, in start
    File ?Reporter.py?, line 491, in probe
    IndexError: list index out of range
    2021-06-06 23:59:13.111 - ERROR - HWN025032E Job failed during
    post processing of collected data from the data source.
    
    A fix for this has been identified and will be corrected.
    ____________________________________________________
    The defect is against component: 5608TPCSI
    Server/Manager build/release: 5.4.x
    Problem as described by customer: PureStorage X20 probe failures
    
    Initial customer impact (low/med/high): med
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users monitoring Pure storage device    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Storage Insights users are not able to run add and probe     *
    * a newly added PureStorage X20 storage array.                 *
    *                                                              *
    * Probe failure messaging visible in GUI is as follows:        *
    *                                                              *
    * BTADS0102E The probe with the run ID value completed with    *
    * errors.                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 3Q21   [ 54X-IBM-SI ]
    
    ( release target 3Q 2021 / July)
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT37257

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    541

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-14

  • Closed date

    2021-07-02

  • Last modified date

    2021-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]