IBM Support

OA61575: OPTION REFRESHMODE(INTERNAL) CAUSES ENTIRE SYSPRRPT TO BE COPIEDTO C2PDEBUG

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • option refreshmode(internal) causes entire SYSPRRPT to be copied
    to C2PDEBUG at each environment refresh.
    
    Also, when the UI is used to set "Use internal refresh" to N (or
    blank), no explicit option refreshmode(external) is generated so
    a REFRESH of the alert configuration does not change the
    refreshmode from internal if that has been previously set.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of zSecure Alert with "Enhancements    *
    *                 for compliance automation and usability" fix *
    *                 applied (as provided by APAR OA60419).       *
    ****************************************************************
    * PROBLEM DESCRIPTION: zSecure Alert started task copies the   *
    *                      entire SYSPRRPT to C2PDEBUG at each     *
    *                      environment refresh in cases where      *
    *                      the 'refreshmode' configuration option  *
    *                      is set to 'internal' and setting the    *
    *                      alert UI configuration option           *
    *                      "Use internal refresh" to 'N' does not  *
    *                      perform as expected.                    *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF provided.                      *
    ****************************************************************
    When zSecure Alert configuration option 'refreshmode' is set to
    'internal', zSecure Alert started task copies the entire
    SYSPRRPT to C2PDEBUG at each environment refresh. The "Use
    internal refresh" UI configuration option does not perform as
    expected so that setting it to 'N' does not result in
    a 'refreshmode(external)' alert configuration statement to be
    generated.
    

Problem conclusion

  • zSecure Alert and its configuration interface have been modified
    so fix the reported issues.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA61575

  • Reported component name

    ZSEC BASE,ADMIN

  • Reported component ID

    5655T0100

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-09

  • Closed date

    2021-08-12

  • Last modified date

    2021-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ06253

Modules/Macros

  • C2PRPTRT C2PSPARM
    

Fix information

  • Fixed component name

    ZSEC BASE,ADMIN

  • Fixed component ID

    5655T0100

Applicable component levels

  • R240 PSY UJ06253

       UP21/08/13 P F108

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"240"}]

Document Information

Modified date:
02 September 2021