IBM Support

IT36934: BACKUPS OF VIRTUAL MACHINES CAN FAIL WITH ANS4174E RC=2070 AFTER UPGRADING TO 8.1.11.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • IBM Spectrum Protect for Virtual Environments - Data Protection
    for VMware  8.1.11 backups can fail with the following messages
    seen in the data mover node error log:
    
    ANS0246E Issue dsmEndTxn and then begin a new transaction
    session.
    ANS0361I DIAG: ..\..\common\vm\vmbackcommon.cpp(3595):
    VmBackupControlFiles(): Error 2070 sending
    ANS4174E Full VM backup of VMware Virtual Machine failed with
    RC=2070 mode=Incremental Forever - Incremental, target node
    name=? DC_node_name?, data mover node name=?DM_node_name?
    ANS1228E Sending of object failed.
    ANS0246E Issue dsmEndTxn and then begin a new transaction
    session.
    ANS0246E Issue dsmEndTxn and then begin a new transaction
    session.
    ANS0361I DIAG: ..\..\common\vm\vmbackcommon.cpp(3595):
    VmBackupControlFiles(): Error 2070 sending
    ANS4174E Full VM backup of VMware Virtual Machine failed with
    RC=2070 mode=Incremental Forever - Incremental, target node
    name=? DC_node_name?, data mover node name=?DM_node_name?
    ANS1228E Sending of object failed.
    ANS0246E Issue dsmEndTxn and then begin a new transaction
    session.
    | MDVREGR 8.1.11-TIV_5725TVEVM |
    
    IBM Spectrum Protect Versions Affected:
    IBM Spectrum Protect for Virtual Environments - Data Protection
    for VMware version 8.1.11.0 on Windows and Linux
    
    Initial Impact: Medium
    
    Additional Keywords: TSM, Tivoli, Storage, Manager, TS005053048,
    Spectrum Protect, TDP4VE .
    

Local fix

  • The local fix consists of several steps, depending on the
    current configured options. The backup will fail when either the
    TXNBytelimit or the TXNGroupmax limit is reached.
    
    1. Verify no TXNBytelimit is set for the datamover. Remove the
    option from the datamover dsm.opt and verify if the backups are
    working now. If the backup still fails, continue with step 2
    2.Query the DC node from the server side, to know the used
    TXNGroupmax value.
    3. Increase TXNGroupmax on the for the used DC node to a higher
    value, e.g. 6144
      update node <datacenter node name>  TXNGroupmax=6144
       Verify if the backup is working now. If still failing,
    continue with step 4.
    4. Increase TXNGroupmax with increments of 2048 until the backup
    is working.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Protect for Virtual Environments Data           *
    * Protection for VMware versions 8.1.11 and 8.1.12 running on  *
    * all Microsoft Windows x64 and Linux x86 platforms.           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * This issue is projected to be fixed in the Data Protection   *
    * for VMware Data Mover version 8.1.13 on Windows x64 and      *
    * Linux x86 platforms.                                         *
    * Note 1: This is subject to change at the discretion of IBM.  *
    ****************************************************************
    

Problem conclusion

  • Txn limits are now correctly checked when sending control files.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT36934

  • Reported component name

    TSM FOR VE DP V

  • Reported component ID

    5725TVEVM

  • Reported release

    81W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-05-18

  • Closed date

    2021-05-28

  • Last modified date

    2021-05-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • dsmagent
    

Fix information

  • Fixed component name

    TSM FOR VE DP V

  • Fixed component ID

    5725TVEVM

Applicable component levels

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS8TDQ","label":"Tivoli Storage Manager for Virtual Environments"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81W"}]

Document Information

Modified date: