A fix is available
APAR status
Closed as program error.
Error description
1) Some time fields in IMS x'450A' knowledge modules were formatted incorrectly as STCK units, when the fields actually contained Microsecond values. 2) A change in record layout resulted in some IMS x'4033' records not being formatted correctly. This is a retrofit of IMS PI V250 APAR PH37547.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Problem Investigator V2.4 * **************************************************************** * PROBLEM DESCRIPTION: 1. Some time fields in IMS x'450A' * * formatted incorrectly. * * 2. Formatting errors in some IMS * * x'4033' records. * **************************************************************** 1. Some time fields in IMS x'450A' KM were formatted incorrectly as STCK units, when the fields actually contained Microsecond values. 2. A change in record layout resulted in some IMS x'4033' records not being formatted correctly.
Problem conclusion
1. Correct IMS x'450A' KM to correctly format values as Microseconds. 2. Retro-fit of IMS PI V2.5 APAR PH37547 to correct formatting of IMS x'4033' record.
Temporary fix
Comments
APAR Information
APAR number
PH37352
Reported component name
IMS PROBLEM INV
Reported component ID
5655K5000
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-18
Closed date
2021-05-27
Last modified date
2021-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI75608
Modules/Macros
ALZ4033A ALZ4033B ALZ4033C ALZ4033D ALZ4033E ALZ4033F ALZ450AA ALZ450AB ALZ450AC ALZ450AD ALZ450AE ALZ450AF
Fix information
Fixed component name
IMS PROBLEM INV
Fixed component ID
5655K5000
Applicable component levels
R240 PSY UI75608
UP21/06/08 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.