IBM Support

PH37333: THE COMPILER PRODUCES MORE THAN ONE IGYCB7311-W MESSAGE FOR THE DATA ITEM ON A GIVEN LINE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM DESCRIPTION: The compiler produces more than one
    IGYCB7311-W message for the data item on a given time.
    
    USERS AFFECTED: Users of IBM Enterprise COBOL 6.x compiling
    programs with INITCHECK that contain statements that use the
    same data item more than once.
    
    PROBLEM SUMMARY: The compiler checks each use of every data item
     and reports all places where each data items is uninitialized.
    If a data item is used more than once on the same COBOL
    statement, the compiler sees that as two different uses and
    reports it multiple times.
    
    CONCLUSION: The compiler was fixed so that uninitialized data
    items are only reported once per line. Note that if two distinct
    data items with the same name are used on a single COBOL
    statement and are uninitialized, the compiler will generate a
    message for each.
    

Local fix

  • WORKAROUND/CIRCUMVENTION: Compile with NOINITCHECK or ignore the
     duplicate message.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Enterprise COBOL 6.3 compiling  *
    *                 programs with INITCHECK that contain         *
    *                 statements that use the same data item more  *
    *                 than once.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The compiler produces more than one     *
    *                      IGYCB7311-W message for the data item   *
    *                      on a given line.                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler checks each use of every data item and reports all
    places where each data items is uninitialized. If a data item is
    used more than once on the same COBOL statement, the compiler
    sees that as two different uses and reports it multiple times.
    

Problem conclusion

  • The compiler was fixed so that uninitialized data items are only
    reported once per line. Note that if two distinct data items
    with the same name are used on a single COBOL statement and are
    uninitialized, the compiler will generate a message for each.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH37333

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-05-18

  • Closed date

    2021-05-19

  • Last modified date

    2021-06-02

  • APAR is sysrouted FROM one or more of the following:

    PH35977

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI  IGYCOPT  IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU
    IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI75468

       UP21/05/29 P F105

  • R631 PSY UI75469

       UP21/05/29 P F105

  • R632 PSY UI75470

       UP21/05/29 P F105

  • R63H PSY UI75471

       UP21/05/29 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023