Error description
Dynamic Test Runner internal defects and enhancements
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 01.All clients that use * * program-to-program interception. * * 02.All clients that use * * program-to-program interception. * * 03.All clients. * * 04.All clients that record/replay IMS * * applications. * * 05.All clients that use * * program-to-program interception. * * 06.All clients. * **************************************************************** * PROBLEM DESCRIPTION: 01.Detecting length of subsystem call * * arguments is manual and labor * * intensive, and might depend on * * argument values or pointer values. * * 02.Subsystem call arguments are named * * with ordinal numbers. * * 03.Collection on a large number of CICS * * transactions at the same time * * generates very large recording data * * set. * * 04.The detection of DB vs GSAM PCB was * * imprecise. * * 05.Program-to-program interception * * configuration is manual and labor * * intensive. * * 06.The results from collection and * * replay are sometimes difficult to * * decipher. * **************************************************************** 01.Clients have to manually specify the length and location of each argument in subsystem calls. This release introduces a configuration property that offers flexibility in specifying the argument location and length. 02.The arguments in subsystem calls are currently named with a prefix and an ordinal number. This releases properly names arguments that come from common control blocks in CICS, Db2, IMS, MQ and file systems. 03.Clients that wish to collect a large number of CICS transaction in one recording were advised not to. This release introduces a new transaction (BZUX) which limits the number of instances of each transaction, allowing large number of CICS transactions to be recorded. 04.The parsing of PCB metadata would not always correctly identify DB vs GSAM data store access. This release corrects the issue allow correct return code handling on the IMS subsystem calls. 05.Clients have to manually specify all program-to-program interception in configuration files. This release automates the program-to-program interception for COBOL. 06.The output from collection and replay runs has two formats: SYSOUT report and binary recording data set. Clients have, in some instances, had a difficult time interpreting the results. This release adds an optional feature which presents the results in an easy to consume, web browser interface.
Problem conclusion
01.Automation added to assist the client. 02.Automation added to assist the client. 03.CICS recording scale for transactions increased. 04.Problem corrected. 05.Automation added to assist the client. 06.Automation added to assist the client.
Temporary fix
Comments
APAR Information
APAR number
PH37212
Reported component name
VIRT TEST PLTFM
Reported component ID
5724T0763
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-13
Closed date
2021-06-16
Last modified date
2021-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI75928
Modules/Macros
BZU1SMPE BZU2EXEC BZU2LAYR BZU2THIN BZU2TLYR BZU3ALOC BZU6DDEF BZUACAF@ BZUADSMF BZUAEIN@ BZUAETR@ BZUAINIT BZUAIP2 BZUAIPI BZUAIPS BZUAIPX BZUALLOC BZUAPIPI BZUAPRC2 BZUAPRCA BZUAPRCD BZUAPRCX BZUAPRH@ BZUAPRS@ BZUARGID BZUARRS@ BZUARSMF BZUARST0 BZUARST1 BZUARST2 BZUARST3 BZUARST4 BZUARST5 BZUARST6 BZUARST7 BZUARST8 BZUARST9 BZUASSRT BZUASTB0 BZUASTB1 BZUASTB2 BZUASTB3 BZUASTB4 BZUASTB5 BZUASTB6 BZUASTB7 BZUASTB8 BZUASTB9 BZUASTC0 BZUASTC1 BZUASTC2 BZUASTC3 BZUASTC4 BZUASTC5 BZUASTC6 BZUASTC7 BZUASTC8 BZUASTC9 BZUASTMD BZUASTMP BZUASTUB BZUASTUC BZUAVRDT BZUBATCH BZUBCON@ BZUBCP BZUBDSC@ BZUBSRV@ BZUCBCBL BZUCBPL1 BZUCCDFN BZUCCINT BZUCCOLL BZUCDEFN BZUCF410 BZUCF420 BZUCF510 BZUCF520 BZUCF530 BZUCF540 BZUCF550 BZUCF560 BZUCI410 BZUCI420 BZUCI510 BZUCI520 BZUCI530 BZUCI540 BZUCI550 BZUCI560 BZUCICPT BZUCICSA BZUCICSL BZUCICSN BZUCICSS BZUCICST BZUCICSW BZUCICSX BZUCIDFN BZUCIDRI BZUCIDRP BZUCIDRR BZUCIDRS BZUCIDRT BZUCO410 BZUCO420 BZUCO510 BZUCO520 BZUCO530 BZUCO540 BZUCO550 BZUCO560 BZUCPLTI BZUCPLTS BZUCPLTT BZUCRECS BZUCRECT BZUCSD BZUCSTUB BZUDB2ST BZUDCP BZUDLAYR BZUDTHIN BZUDTLYR BZUDYNAL BZUECP BZUESPIE BZUESPR@ BZUESTAE BZUGTARG BZUGTMEM BZUHFIO@ BZUHFIOH BZUHFIOP BZUHPRN@ BZUII410 BZUII420 BZUII510 BZUII520 BZUII530 BZUII540 BZUII550 BZUII560 BZUIMSSB BZUIMSSE BZUIMSSF BZUIMSTR BZUIMSVN BZUIMSVR BZUINCL BZUIO410 BZUIO420 BZUIO510 BZUIO520 BZUIO530 BZUIO540 BZUIO550 BZUIO560 BZUISVI0 BZUITERC BZUITERP BZUJFIOH BZUJFIOP BZUKFIO@ BZUKFIOH BZUKFIOP BZULCEE BZULDB2 BZULEOPT BZULFIOH BZULFIOP BZULIMS BZULLE BZULMQ BZUMCP BZUMETA BZUMSGEN BZUPBCP BZUPBMP BZUPDB2 BZUPDCP BZUPDLI BZUPECP BZUPLAY BZUPMCP BZUPPLAY BZUPRH00 BZUPRH0@ BZURCP BZURI410 BZURI420 BZURI510 BZURI520 BZURI530 BZURI540 BZURI550 BZURI560 BZURO410 BZURO420 BZURO510 BZURO520 BZURO530 BZURO540 BZURO550 BZURO560 BZURPLAY BZURRCP BZURTCP BZURUN BZUSCFG BZUSCP BZUSETUP BZUSLAYR BZUSTLYR BZUSUDSN BZUSYSIN BZUTCP BZUTRACE BZUUFIOH BZUUFIOP BZUUMODC BZUUMODD BZUUMODI BZUUMODL BZUVERS BZUVFIOH BZUVFIOP BZUVRM BZUVSAM BZUWFIOH BZUWFIOP BZUXC410 BZUXC420 BZUXC510 BZUXC520 BZUXC530 BZUXC540 BZUXC550 BZUXC560 BZUXCOLL BZUZFIO@ BZUZFIOH BZUZFIOP
Fix information
Fixed component name
VIRT TEST PLTFM
Fixed component ID
5724T0763
Applicable component levels
R100 PSY UI75928
UP21/06/19 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Type":"MASTER","Line of Business":{"code":"","label":""},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]
Document Information
Modified date: