APAR status
Closed as program error.
Error description
Unexpected device removal alerts from Storage Insights were generated for the internal resources for a DS8000 after a daily probe completed. Internal resources are no longer listed for the storage device in Storage Insights and performance monitoring stopped collecting data. Example: Alert Storage System Deleted Volume has been triggered. The probe completed successfully but contained a warning. HWNEP1132W Can?t collect further system information because the device returned unexpected values. The underlying error was logged in traceProbe_ExternalProcess_0.log [EP_DS_CLI_Probe.getStorageServers] [ERROR] Retrieved empty MicrocodeLevel for lpar: <lpar> As a result of the empty microcode level, the probe did not collect all of the internal resources and sent alerts to indicate that they were no longer found. Since the FC ports were not found, performance monitoring stopped working. Restarting the data collection will start a new probe. If the condition causing the DS8000 microcode level to be blank has been resolved on the storage side, the internal resources will be found and performance monitoring will resume after the probe completes. This APAR is a continuation of the fix for APAR IT33891. IT33891: DS8000 PROBES FAIL WHEN MICROCODE VERSION INFORMATION IS BLANK https://www.ibm.com/support/pages/apar/IT33891
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Storage Insights users probing DS8000 device * **************************************************************** * PROBLEM DESCRIPTION: * * Storage Insights generated unexpected device removal * * alerts for internal resources of DS8000 device following * * daily probes. Internal resources are no longer listed for * * the storage device in Storage Insights and performance * * monitoring stopped collecting data. * * * * Example: * * Alert Storage System Deleted Volume has been * * triggered. * * * * The probe completed successfully but contained a * * warning. * * * * HWNEP1132W Can't collect further system information * * because the device returned unexpected values. * * * * As a result of the empty microcode level, the probe did * * not collect all of the internal resources and sent alerts to * * * * indicate that they were no longer found. Since the FC * * ports were not found, performance monitoring stopped * * working. * * Restarting the data collection will start a new probe. If * * the condition causing the DS8000 microcode level to be * * blank has been resolved on the storage side, the internal * * resources will be found and performance monitoring will * * resume after the probe completes. * * * * * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following release: IBM Storage Insights 2Q21 [ 54X-IBM-SI ] ( release target 2Q 2021 / June ) The target dates for future releases do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT36363
Reported component name
STORAGE INSIGHT
Reported component ID
5608TPCSI
Reported release
541
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-25
Closed date
2021-06-24
Last modified date
2021-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STORAGE INSIGHT
Fixed component ID
5608TPCSI
Applicable component levels
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"541"}]
Document Information
Modified date:
08 February 2022