IT35836: API CONNECT GATEWAY SERVICE CAN GET STUCK IN A NON-RESPONSIVE STATE WHEN DRR FINISH NOT DETECTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If API Connect Gateway Service (apic-gw-service) is restarted
    while it is processing a Dynamic Re-registration and
    Reconfiguration (DRR), it can get stuck waiting for that DRR to
    complete.
    
    
    lib:gateway-controller:apigateway:GatewayExtensionDeployer:
    updateDynamicReconfigurationStatus(): dynamicReconfiguration
    result: {"pending":true,"timestamp":1604365673643}
    lib:gateway-c
    ontroller:apigateway:GatewayExtensionDeployer:
    updateDynamicReconfigurationStatus(): DYNAMIC_RECONFIG_PENDING
    = false && pending =
    true
    lib:gateway-controller:apigateway:GatewayExtensionDeployer:
    DRR has been signaled, deferring extension deployer
    initialization until DRR is complete
    
    Because the
    apic-gw-service was restarted in the middle of the DRR, that
    DRR will never complete.
    

Local fix

  • Trigger another DRR, wait for "Registration configuration was
    successful" message from apic-gw-service, and then enable any
    newly deployed gateway extensions by restarting the
    apic-gw-service
    

Problem summary

  • The GatewayExtensionDeployer may wait for DRR to complete
    unexpectedly if APIC Gateway Service restarts in the middle of a
    DRR.
    

Problem conclusion

  • Fixed in 10.0.1.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT35836

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    A0X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-02-08

  • Closed date

    2021-03-30

  • Last modified date

    2021-03-31

  • APAR is sysrouted FROM one or more of the following:

    LI81847

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • RA0X PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A0X"}]

Document Information

Modified date: