IT35302: ODBC ORACLE INSERT FAILS WITH RIGHT TRUNCATION OF CHAR DATA FOLLOWING A DATE COLUMN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • With the DataDirect Oracle ODBC driver v08.02.2330 that is
    included in IIB v10.0.0.22 and ACE v11.0.0.10, an insert that
    includes a varchar2 column followed by a DATE column may fail
    with a string truncation error:
    
    BIP2322E: Database error: SQL
    State '22001'; Native Error Code '0'; Error Text '[IBM][ODBC
    Oracle Wire Protocol driver]String data, right truncated. Error
    in parameter X.'.
    

Local fix

  • Use the Oracle ODBC driver from an earlier Fix Pack.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v10 and IBM App Connect
    Enterprise v11 using ODBC connectivity to Oracle.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    With the DataDirect Oracle ODBC driver v08.02.2330 that is
    included in IBM Integration Bus v10.0.0.22 and IBM App Connect
    Enterprise v11.0.0.10, an insert that includes a varchar2 column
    followed by a DATE column may fail with a string truncation
    error:
    
    BIP2322E: Database error: SQL State '22001'; Native Error Code
    '0';
    Error Text '[IBM][ODBC Oracle Wire Protocol driver]String data,
    right truncated. Error in parameter X.'.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT35302

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-12-17

  • Closed date

    2021-03-23

  • Last modified date

    2021-03-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
24 March 2021