A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4-11 at CQM#BCMX+156CC at Shutdown.
Local fix
Remove SHUTDOWN_DIAGNOSTICS(Y) - from the CQM PARMS and not issue other CQM commands during CQM shutdown such as F cqmstc,DDX.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Db2 Query Monitor for z/OS * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4-11 in CQM#BCMX+156CC * **************************************************************** SHUTDOWN DIAGNOSTICS processing was attempting to report on some module levels loaded into the QM address space that had been previously deleted from the memory.
Problem conclusion
Logic was changed to report only those modules which are still in memory. Search Keywords: ABEND 0C4 SHUTDOWN_DIAGNOSTICS(Y)
Temporary fix
Comments
APAR Information
APAR number
PH28446
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-12
Closed date
2020-11-19
Last modified date
2020-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQM#BCMX CQM#COMX CQM#PARM CQM$$PRM CQMMINIX CQMMSRCX CQMPARMS
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI72672
UP20/11/26 P F011
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0"}]
Document Information
Modified date: