Error description

  • This fix disables the obsolete "FORCE(M)" CQMPARM.
    When QM is attempted to start using this obsolete CQMPARM, the
    startup attempt will now fail and will be accompanied by 2
    error messages:
    *
      1) CQM2101E - PARAMETER ERROR DETECTED FOR FORCE
      2) CQM2110E - TERMINATING DUE TO ERRORS IN CQMPARMS INPUT
    *
    The first (CQM2102E) indicates the invalid use of an obsolete
    parameter in the CQMPARMs.  The second (CQM2110E) to indicate
    that QM cannot continue and is terminating - again, due to the
    use of an obsolete CQMPARM.
    

Local fix

  • Remove obsolete FORCE(M) parm in CQMPARMS and cycle DB2 to make
    change effective.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: This fix disables the obsolete          *
    *                      "FORCE(M)" CQMPARM. When QM is          *
    *                      attempted to start using this obsolete  *
    *                      CQMPARM, the startup attempt will now   *
    *                      fail and will be accompanied by 2       *
    *                      error messages:                         *
    *                                                              *
    *                        1. CQM2101E - PARAMETER ERROR         *
    *                          DETECTED FOR FORCE                  *
    *                        2. CQM2110E - TERMINATING DUE TO      *
    *                          ERRORS IN CQMPARMS INPUT            *
    *                                                              *
    *                      The first (CQM2102E) indicates the      *
    *                      invalid use of an obsolete parameter in *
    *                      the CQMPARMs.  The second (CQM2110E) to *
    *                      indicate that QM cannot continue and is *
    *                      terminating - again, due to the use of  *
    *                      an obsolete CQMPARM.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK09132

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-07-19

  • Closed date

    2005-08-10

  • Last modified date

    2005-09-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK06168

Modules/Macros

  •    CQM#PARM
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R210 PSY UK06168

       UP05/08/17 P F508

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]

Document Information

Modified date:
17 March 2021