A fix is available
APAR status
Closed as program error.
Error description
The following error can occur with JSON GENERATE: IGYCB7104-U Internal error while compiling function xxxxxxxx. Failed assertion on ilgen/WCodeIlGenerator2.cpp:4823. Sample code: JSON GENERATE WS-JSON-OUTPUT FROM itemUpdateList.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling * * programs containing JSON GENERATE or XML * * GENERATE, where the input COBOL data * * item (identifier-2) is an UNBOUNDED OCCURS * * group item that contains another nested * * OCCURS item. * **************************************************************** * PROBLEM DESCRIPTION: A compile time terminating error * * message is generated by the compiler * * with message number IGYCB7104-U. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** An internal compiler error was encountered during compilation in the circumstances identified above, and a terminating error message was generated.
Problem conclusion
The compiler was fixed.
Temporary fix
Comments
APAR Information
APAR number
PH34586
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-17
Closed date
2021-03-23
Last modified date
2021-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74566 UI74567 UI74568 UI74569 PH36686
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI74566
UP21/03/30 P F103
R631 PSY UI74567
UP21/03/30 P F103
R632 PSY UI74568
UP21/03/30 P F103
R63H PSY UI74569
UP21/03/30 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023