A fix is available
APAR status
Closed as program error.
Error description
Restarting a domain through any method then quiescing can result in the service showing as available in the self balancing table which will result in failed requests.
Local fix
Unquiesce then admin state disable to take the object(s) or domain(s) down.
Problem summary
DataPower Standby Control might fail to assign the Weight value properly if the operational state of the front protocol handler or it's domain is quiesed or disabled when the Standby Group being off.
Problem conclusion
Fixed in 2018.4.1.15, 10.0.1.2
Temporary fix
Comments
APAR Information
APAR number
IT33856
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-10
Closed date
2021-01-26
Last modified date
2021-01-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
RA0X PSY
UP