A fix is available
APAR status
Closed as program error.
Error description
You are adding or updating definitions in you CPSM CICSPlex environment. Your CMAS produces an SVC dump, and the following messages appear in the CMAS job output: EYUXL0900I Starting Environment Recovery EYUXL0905E cmasid ASRA IN XDCR, OFFSET ???????? PSW=07850000 80000002 EYUXL0905E INTC=0001 ILC=2 TXCP=69F9F401 SCODE=S00C1 TRAN=XDNR TASK=0012345 EYUXL0905E Methods=XDCR,XDSG,TAAC,XLSD,XLSI,MOMS,XDH2,XDNR, EYUXL0905E Methods=XLOP EYUXL0905E BEAR=203548DC, OFFSET=???????? EYUXL0906I Registers at ABEND EYUXL0907I GPR0-GPR1 00000000_20A0FF68 00000000_20A0E4E0 EYUXL0907I GPR2-GPR3 00000000_00000004 00000000_203535C8 EYUXL0907I GPR4-GPR5 00000000_1FECAE00 00000000_1FEB9700 EYUXL0907I GPR6-GPR7 00000000_20CD7E40 00000000_20A0E010 EYUXL0907I GPR8-GPR9 00000000_000C0000 00000000_20353588 EYUXL0907I GPRA-GPRB 00000000_1FEB8500 00000000_203545C8 EYUXL0907I GPRC-GPRD 00000000_20A0C560 00000000_20A0E010 EYUXL0907I GPRE-GPRF FF000070_00000000 00000000_1FDEB610 Notice the PSW points to low core, and the value in 32-bit portion of register 14 is 00000000. The BEAR address will point to a BR instruction in the generated exit code at label DRCR_PRODUCE_TRACE. The list of methods in TASK view of the abending task, seen by VERBX EYU9D### 'TASKS,JOB=cmasjob' looks like this: Kernel linkage summary for component - DAT / Data Definition Task Meth 12345 XLOP 12345 XDNR 12345 XDH2 12345 MOMS 12345 XLSI 12345 XLSD 12345 TAAC 12345 XDSG 12345 XDCR
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS CPSM users * **************************************************************** * PROBLEM DESCRIPTION: When writing to the repository and * * encountering it being full the CMAS * * branches to low storage and issues an * * ABEND S0C1 with a PSW address of 2. * * * * The msg "EYUXD0011S (applid) The Data * * Repository is full, all further * * modifications will fail. The Repository * * must be expanded." may be produced. * * * * The job writing to the REPOSITORY ends * * with return code 8 and a code of * * EXCEPTION. * **************************************************************** * RECOMMENDATION: All CMASs should be restarted to apply the * * fix. The restarts do not need to occur at * * the same time, and can occur in any order. * **************************************************************** Due to bad code in EYU0XDCR which incorrectly enters a subroutine without the correct linkage. The subroutine branches back to low storage and ABENDs S0C1.
Problem conclusion
EYU0XDCR has been updated to correct the subroutine linkage.
Temporary fix
Comments
APAR Information
APAR number
PH33178
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
20M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2021-01-08
Closed date
2021-02-01
Last modified date
2021-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI73697 UI73698
Modules/Macros
EYU0XDCR
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5"}]
Document Information
Modified date:
06 March 2021