Direct links to fixes
APAR status
Closed as program error.
Error description
Changing in-basket sort order of work items during runtime from the sort order defined during design time, the "Open next work item" action will fail to retrieve subsequent work items in the new sort order. Steps to reproduce: 1. Create multiple sortable columns in the in-basket, set Time Create Ascending as default 2. In the Work Details page, add the "Open Next Work Item" to the Work Item Toolbar 3. Deploy the solution 4. Create several cases, 4 or 5 should suffice 5. Sort the in-basket by a different column such that the order is different than the default sort order 6. Ensure new sort order is not the same order as default sort order 7. Open and complete the first item from the newly sorted list Expected result The next item on the new sort order is presented to the user to process Actual result The next item from the previous default sort order is presented to the user to process
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Case client users with auto get next work item enabled * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * It is recommended to apply 65.2.1.6-ICM-FP006 or later to * * address this issue. * ****************************************************************
Problem conclusion
This issue has been corrected in 5.2.1.6-ICM-FP006 and later releases. The automatic get next will retrieve the next work item based on the current order of the work items from the in-basket.
Temporary fix
Comments
APAR Information
APAR number
PJ44459
Reported component name
CASE MGR CLIENT
Reported component ID
5725A1501
Reported release
521
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-18
Closed date
2017-03-15
Last modified date
2017-03-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CASE MGR CLIENT
Fixed component ID
5725A1501
Applicable component levels
R521 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSCTJ4","label":"IBM Case Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"521"}]
Document Information
Modified date:
04 January 2021