IBM Support

VM66316: INPUT REGISTER NOT LOADED FOR BLOCK DIAGNOSE I/O ON EAV DEVICE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • VM65943 added minidisk support for extended address volumes
    (EAV), 3390-A devices, supporting 28-bit cylinder addresses.
    The code in HCPDPV which is used for Diagnose Block I/O
    processing for EAV minidisks fails to load an input register
    correctly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Block Diagnose I/O on EAV       *
    *                 devices                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    Input register that should contain the address of the RDEV for
    subroutine BLDEFE is not correctly loaded.
    

Problem conclusion

  • The code in HCPDPV has been corrected to properly load the RDEV
    input register for subroutine BLDEFE.  For z/VM 6.4.0, this
    APAR is only applicable if new function APAR VM65943, CP
    Support for EAV minidisk is applied.
    

Temporary fix

  • *********
    * HIPER *
    *********
    FOR RELEASE VM/ESA CP/ESA R640 :
    PREREQ: VM65943
    CO-REQ: NONE
    IF-REQ: NONE
    FOR RELEASE VM/ESACP/ESAR710 :
    PREREQ: NONE
    CO-REQ: NONE
    IF-REQ: NONE
    

Comments

APAR Information

  • APAR number

    VM66316

  • Reported component name

    VM CP

  • Reported component ID

    568411202

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-08-15

  • Closed date

    2019-09-03

  • Last modified date

    2020-12-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM35520 UM35523

Modules/Macros

  • HCPDPV
    

Fix information

  • Fixed component name

    VM CP

  • Fixed component ID

    568411202

Applicable component levels

  • R640 PSY UM35520

       UP19/09/26 P 2001 ¢

  • R710 PSY UM35523

       UP19/09/26 P 2001 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.