A fix is available
APAR status
Closed as program error.
Error description
An unexpected error from the directory manager (RC=596) will trigger SMSTATUS to be executed in the SMAPI Worker Server before returning the results to the calling program. This may cause the original API request to time out while the SMSTATUS is executing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Any SMAPI user using DirMaint are affected. * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** An unexpected error from the directory manager (RC=596) will trigger SMSTATUS to be executed in the SMAPI Worker Server before returning the results to the calling program. This may cause the original API request to time out while the SMSTATUS is executing.
Problem conclusion
If DMSWSCHK is not running in the SMAPI Guard server, then exit processing. DMSWSCHK should only ever run on VSMGUARD.
Temporary fix
Comments
APAR Information
APAR number
VM66339
Reported component name
VM CMS
Reported component ID
568411201
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-06
Closed date
2020-02-19
Last modified date
2020-12-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM35599 UM35600
Modules/Macros
DMSWSCHK
Fix information
Fixed component name
VM CMS
Fixed component ID
568411201
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.