A fix is available
APAR status
Closed as program error.
Error description
When compiling with OPT(1) or OPT(2), compiler terminates with following messages: IGYAS5125-U The compilation was terminated due to a compiler error in phase id: "IGYCASMB". IGYAS5295-U The compilation failed due to an internal error detected in the compiler back-end. The error code was 267.
Local fix
Use OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling * * programs at OPT(1|2) that have multiple * * PERFORM statements PERFORMing a * * paragraph or section. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYAS5125-U The compilation * * was terminated due to a compiler error * * in phase id: "IGYCASMB". * * IGYAS5295-U The compilation * * failed due to an internal error * * detected in the compiler back-end. * * The error code was 267. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler's internal state was incorrect before inlining PERFORMed paragraphs or sections. The compiler aborted when the incorrect internal state was detected.
Problem conclusion
The compiler was fixed to have the correct internal state before inlining PERFORMed paragraphs or sections.
Temporary fix
Comments
APAR Information
APAR number
PH31471
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-10
Closed date
2020-11-23
Last modified date
2020-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYMSGXT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI72712
UP20/11/28 P F011
R631 PSY UI72713
UP20/11/28 P F011
R632 PSY UI72714
UP20/11/28 P F011
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023