A fix is available
APAR status
Closed as new function.
Error description
When running in AMODE31 within DFHEIENT, there is the following code that restores R1, which is the Parameter list passed from the calling program: ST 13,DFHEISA-DFHEISTG+4(,1) CHAIN TO CALLER'S @F8E1S @L2A LR 15,1 ADDRESS OF STORAGE @F8E1S @L2A ICM 1,B'1111',24(13) RESTORE INPUT REGISTER 1 @F8E1S @L2A However in the AMODE64 section, there are no such instructions. Because CICS also allows linkage between AMODE(64) and AMODE(31) or even AMODE(24) programs, it is possible to provide service routines that handle data in 64-bit storage without rewriting other parts of the application. Therefore DFHEIENT should preserve R1 regardless of the AMODE. Additional Symptom(s) Search Keyword(s): KIXREVBDB
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: In AMODE 64 specifically, the DFHEIENT * * macro does not restore Register 1 as it * * completes. * * * * This means that any optional parameters * * passed by the calling program are not * * accessible via the address that is held * * in Register 1. * **************************************************************** With the introduction of AMODE 64 the DFHEIENT macro was updated to support 64-bit, but it did not restore Register 1 to the value that it had saved on entry. No error is generated but the result after DFHEIENT completes is that Register 1 does not hold an address pointing to the EIB and COMMAREA, plus any optional parameters that may have been passed to the program, as is expected and as already happens with AMODE 24 and AMODE 31.
Problem conclusion
The DFHEIENT macro has been updated so that Register 1 is now restored in the AMODE 64 code-path and any optional parameters can now be accessed via that address.
Temporary fix
Comments
APAR Information
APAR number
PH31178
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-02
Closed date
2021-05-14
Last modified date
2021-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI75403 UI75404 UI75405
Modules/Macros
DFHEIENT
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R100 PSY UI75405
UP21/05/15 P F105
R200 PSY UI75404
UP21/05/15 P F105
R300 PSY UI75403
UP21/05/19 P F105
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]
Document Information
Modified date: