IBM Support

PH31016: SUPPRESS MESSAGE IGYOS4097-I FOR "TEST(NODWARF)"

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using the "TEST(NODWARF)" compilation option without any
    other parameter (or with EJPD/NOEJPD), this triggers an
    IGYOS4097-I message:
    
    IGYOS4097-I The TEST suboption values of SOURCE or SEPARATE are
    not allowed when NODWARF is in effect. The supported values of
    NOSOURCE and NOSEPARATE will be used instead.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the V63 Enterprise COBOL compiler   *
    *                 who are compiling with the TEST(NODWARF)     *
    *                 compiler option.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unnecessary output: Some users have     *
    *                      complained about the generation of      *
    *                      message IGYOS4097-I 'The TEST           *
    *                      suboption values of SOURCE or SEPARATE  *
    *                      are not allowed when NODWARF is in      *
    *                      effect.  The supported values of        *
    *                      NOSOURCE and NOSEPARATE will be used    *
    *                      instead.' when compiling with option    *
    *                      TEST(NODWARF), that it doesn't provide  *
    *                      any non-intuitive information and       *
    *                      should be eliminated.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF and recompile     *
    ****************************************************************
    According to the description in the z/OS Enterprise COBOL
    Programming Guide, the default suboptions for the TEST compiler
    option are NOEJPD, DWARF, SOURCE, NOSEPARATE when TEST is
    specified with no suboptions.  When TEST(NODWARF) is specified
    on the compile, the compiler uses the default setting of SOURCE
    since SOURCE | NOSOURCE suboption was not specified.  The SOURCE
    suboption has no meaning with NODWARF, so  the compiler switched
    it to NOSOURCE and put out the I-level message. The information
    in message IGYOS4097-I is confusing, redundant and unnecessary.
    

Problem conclusion

  • The compiler has been changed so that it no longer emits the
    IGYOS4097-I message when TEST(NODWARF) is specified on a
    compile.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH31016

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-30

  • Closed date

    2022-11-23

  • Last modified date

    2022-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI  IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT
    IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI83433

       UP22/12/01 P F211

  • R631 PSY UI83434

       UP22/12/01 P F211

  • R632 PSY UI83435

       UP22/12/01 P F211

Fix is available