PH31045: IGYPS0088-S (OR OTHER) COMPILER ERROR RECEIVED WHEN "AS" IS DEFINED AS A DATA ITEM.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In V6.3, the addition of the "AS FIXED LENGTH" in the USING
    phrase causes a problem when "AS" is used as a data item.
    Because "AS" is not considered a reserved word, the compiler is
    being fixed to properly recognize "AS FIXED LENGTH" and not get
    hung up on "AS".
    

Local fix

  • Change the data item "AS" to another name.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the Enterprise COBOL for z/OS 6.3   *
    *                 compiler whose COBOL programs contain        *
    *                 data items with the name "AS" where the      *
    *                 data item is used on a USING phrase          *
    *                 of the COBOL CALL statement.                 *
    *                 For example:                                 *
    *                 CALL 'program' USING AS                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: The compiler terminates with severe     *
    *                      error message IGYPS0088-S.              *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    An internal compiler problem causes the compiler to improperly
    issue message IGYPS0088-S when a data item with the name "AS"
    is specified on the USING phrase of the CALL statement.
    

Problem conclusion

  • The internal compiler problem was fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH31045

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-28

  • Closed date

    2020-11-23

  • Last modified date

    2020-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYMSGXT
    IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI72712

       UP20/11/28 P F011

  • R631 PSY UI72713

       UP20/11/28 P F011

  • R632 PSY UI72714

       UP20/11/28 P F011

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023