APAR status
Closed as program error.
Error description
When executing the findEJBTimer script, the following error is received: 00000001 EJBTimersComm E CNTR9100E: Exception com.ibm.websphere.management.exception.ConnectorException: com.ibm.ws.management.connector.ipc.RetryCandidateException: java.io.IOException: Connection close: Read failed. Possible end of stream encountered.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server * **************************************************************** * PROBLEM DESCRIPTION: The findEJBTimer script fails with an * * exception during a server write * * operation * * via the IPC Connector. * **************************************************************** * RECOMMENDATION: * **************************************************************** When executing the findEJBTimer script, the following error is received: 00000001 EJBTimersComm E CNTR9100E: Exception com.ibm.websphere.management.exception.ConnectorException: com.ibm.ws.management.connector.ipc.RetryCandidateException: java.io.IOException: Connection close: Read failed. Possible end of stream encountered. This failure is because the server write operation via the IPCConnector has timed out.
Problem conclusion
Added a JVM property (com.ibm.ws.ipc.serverWriteTimeout) By setting it with a value in seconds), the user can increase the timeout of the IPC Connection during a write operation. by default, the value is 60 seconds. The fix for this APAR is targeted for inclusion in fix pack 9.0.5.7 and 8.5.5.19. For more information, see 'Recommended Updates for WebSphere Application Server': https://www.ibm.com/support/pages/node/715553
Temporary fix
Comments
APAR Information
APAR number
PH24460
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-04-15
Closed date
2020-10-22
Last modified date
2020-10-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R800 PSY
UP
R850 PSY
UP
R900 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB45","label":"Automation"}}]