A fix is available
APAR status
Closed as program error.
Error description
The DB2 Utilities Enhancement Tool batch interface program may fail to select a thread for cancelation if the thread only holds a claim on a database object and the cancel specification specifies any database object keyword (e.g. DATABASE, TABLESPACE, etc.).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of UET. * **************************************************************** * PROBLEM DESCRIPTION: * * The DB2 Utilities Enhancement Tool * * batch interface program may fail to * * select a thread for cancelation if * * the thread only holds a claim on a * * database object and the cancel * * specification specifies any * * database object keyword * * (e.g. DATABASE,TABLESPACE, etc.). * * * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
Apply the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK97415
Reported component name
DB2 UTIL ENHANC
Reported component ID
5655T5800
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-09-29
Closed date
2009-12-15
Last modified date
2010-01-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52894
Modules/Macros
ABPBMAIN ABPPAPI ABPPBALC ABPPBATU ABPPBATX ABPPCHCK ABPPCOPY ABPPDITB ABPPDOBJ ABPPEXEC ABPPEXPR ABPPFILE ABPPFSPC ABPPINEX ABPPINIX ABPPIPCV ABPPLINE ABPPLIST ABPPLOAD ABPPMSG ABPPMSGI ABPPOPTS ABPPOSGS ABPPPACT ABPPPDB2 ABPPPFLE ABPPPLCY ABPPPLYX ABPPPREL ABPPPRSE ABPPPSTR ABPPQUIS ABPPREBU ABPPRECO ABPPREOR ABPPSCNV ABPPSTMT ABPPSTRG ABPPTMPL ABPPUNLD ABPPUTLU ABPPUTLX ABPPXMLU ABPRUSQL ABPSDB2I ABPSFLTR ABPSINIT ABPSUSQL ABPUMAIN
Fix information
Fixed component name
DB2 UTIL ENHANC
Fixed component ID
5655T5800
Applicable component levels
R210 PSY UK52894
UP09/12/18 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date: