IBM Support

PM03464: SYSIN AND SYSPRINT ARE UNALLOCATED AFTER DUET INTERCEPT OF DSNUTILB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After the DSNUTILB intercept, when control is returned by DB2
    Utilities Enhancement Tool to the utility program, SYSIN and
    SYSPRINT are no longer allocated.
    
    ADDITIONAL SYMPTOMS
    * calling DSNUTILS or DSNUTILU from an application program may
        fail when UET is active
    * ABENDS05C may occur in DB2 utility with UET active
       (  ABEND0C5       S0C5 )
    * ABENDU4038 can occur in IBM ADMIN TOOL module ADBTEP2
       when UET is active
        (  ABEND4038     U4038 )
    * ABENDS0C4 can occur when running HPU utilities with UET active
        (  ABEND0C4      S0C4  )
    

Local fix

  • Disable DUET or run CHECK DATA under DSNUTILB
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Utilities Enhancement Tool.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: After the DSNUTILB intercept, when      *
    *                      control is returned by DB2 Utilities    *
    *                      Enhancement Tool to the utility         *
    *                      program, SYSIN and SYSPRINT are no      *
    *                      longer allocated.                       *
    *                      ADDITIONAL SYMPTOMS                     *
    *                      * calling DSNUTILS or DSNUTILU from     *
    *                       an application program may fail when   *
    *                       UET is active                          *
    *                      * ABENDS05C may occur in DB2 utility    *
    *                       with UET active (  ABEND0C5 S0C5 )     *
    *                      * ABENDU4038 can occur in IBM ADMIN     *
    *                      TOOL module ADBTEP2 when UET is active  *
    *                          (  ABEND4038 U4038 )                *
    *                      * ABENDS0C4 can occur when running HPU  *
    *                       utilities with UET active              *
    *                          (  ABEND0C4  S0C4  )                *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM03464

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-12-14

  • Closed date

    2010-03-25

  • Last modified date

    2010-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK55586

Modules/Macros

  •    ABPGDYNA ABPMSGEN ABPPUTLX ABPRUSQL ABPSDB2D
    ABPSINIT ABPSUSQL ABPUFSPC ABPUMAIN ABPUSAPI
    

Fix information

  • Fixed component name

    DB2 UTIL ENHANC

  • Fixed component ID

    5655T5800

Applicable component levels

  • R210 PSY UK55586

       UP10/04/02 P F004 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
31 March 2021