Error description
Preconditioning in support of new function. This APAR addresses these issues: 1. V14 of IMS Connect introduces a number of new commands with which the user may dynamically modify resources which are used by IMS Connect Extensions. 2. Pre-routing exit not being called the 4th time for the fallback list. 3. Requirement: Enhance the pre-routing exit interface CEXRBUXT so that in addition to disqualifying a Tmember, it is also able to provide a reason code explaining why the Tmember was disqualified. 4. An abend 0C4 can occur in module CEXTECL if an input message from the Soap Gateway fails to be converted due to a converter error. The input message payload must be larger than 64K for the abend to occur. Preceding the 0C4 was a very large overlay of storage as the length field of an MVCL was negative. This resulted in a later abend in module FUNTDB01 but that may not always be the case depending upon the amount of data overlaid. The abend may be preceded by ICON message HWSA0345E ADAPTER HWSXMLA0 ENCOUNTERED AN ERROR: R=??? 5. Archive job not honoring abnormal termination disposition 6. Locate <portnum> on panel CEXOPSV2 causes dialog error ISPV007 "Invalid data characters. Data for FIXED format variable "PORT" was not FIXED characters." 7. FUN1007E Processing error 000A0206 when REXX command QUERY SESSION and FUNROPTS trace active returns a large amount of output. 8. Alternate Transaction information is not reported by the REXX or ISPF clients. 9. Inconsistent text description shown in CEX5575I 10. CEX5198W appears when ODBM rules based routing is inactive. - Documentation changes related to this APAR can be found at: http://www-01.ibm.com/support/docview.wss?uid=swg21697422&contex t=SSCX88S
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.4 * **************************************************************** * PROBLEM DESCRIPTION: Preconditioning in support of * * new function * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR addresses the following issues: 1.V14 of IMS Connect introduces a number of new commands with which the user may dynamically modify resources which are used by IMS Connect Extensions. 2.Pre-routing exit not being called the 4th time for the fallback list. 3.Requirement: Enhance the pre-routing exit interface (CEXRBUXT) so that in addition to disqualifying a Tmember, they also be able to provide a reason code explaining why the Tmember was disqualified. 4.An abend 0C4 can occur in module CEXTECL if an input message from the Soap Gateway fails to be converted due to a converter error. The input message payload must be larger than 64K for for the abend to occur. Preceding the 0C4 was a very large overlay of storage as the length field of an MVCL was negative. This produced a follow-on abend in module FUNTDB01 but that might not always be the case depending upon the amountof data overlaid. The abend may be preceded by ICON message HWSA0345E ADAPTER HWSXMLA0 ENCOUNTERED AN ERROR: R=??? 5.Archive job not honoring abnormal termination disposition. 6.Locate <portnum> on panel CEXOPSV2 causes dialog error ISPV007 "Invalid data characters. Data for FIXED format variable "PORT" was not FIXED characters." 7. FUN1007E Processing error 000A0206 when REXX command QUERY SESSION and FUNROPTS trace active returns a large amount of output. 8.Alternate Transaction information is not reported by the REXX or ISPF clients. 9.CEX5198W appearing when ODBM rules based routing is inactive. 10.Inconsistent text description shown in CEX5575I.
Problem conclusion
Temporary fix
Comments
The following changes have been made for the above issues: 1.Respond to the new events which report the dynamic changes to resources and update the IMS Connect Extension's internal representation of these resources. 2.Routing process has been changed to call the pre-routing exit correctly. 3.The pre-routing exit (CEXRBUXT) interface is modified to support reason codes. 4.The IRM trace code x'A4' in module CEXTECL has been updated to recognize that the routine has been called after a failure of the XML converter process and to do additional sanity checking of the format of the application payload when it is called. 5.Archive utility abends are no longer masked as CC=12. 6.Corrected definition of PORT variable. 7.Limit FUNROPTS trace records to the available buffer size. 8.Add Alternate Transaction information to the REXX QUERY SESSION response and the ISPF Active Sessions detail page. 9.Corrected logic in CEXMAIN to properly detect that ODBM rules based routing was inactive, also improved the wording of messages CEX5198W and CEX5189W. 10.Format of CEX5575I message has been simplified: CEX5575I IMS Connect has closed the session, RSN=n RSN=1 The IVP received a 0 length record RSN=2 The IVP received TCPIP ERROR number 54
APAR Information
APAR number
PI27852
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED UR1
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-10-16
Closed date
2015-03-16
Last modified date
2015-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI25971
Modules/Macros
CEX#ABOU CEXACLR1 CEXACL10 CEXAUTH0 CEXBDST0 CEXCERE CEXCONS CEXCONSC CEXCONSS CEXCRPF CEXCRSIB CEXCR62 CEXCVDB CEXEVTPR CEXEVTSR CEXEVT01 CEXEXRTR CEXFUNCM CEXGLBLS CEXINTST CEXI09 CEXJARC CEXMAIN CEXMSGL CEXMSGT CEXOPDRV CEXRAPR CEXRBEPL CEXRBUXT CEXRHWS CEXROUT0 CEXRXADR CEXRXENV CEXR111 CEXR112 CEXR168 CEXR771 CEXR772 CEXR773 CEXR774 CEXR775 CEXR776 CEXR777 CEXR778 CEXR779 CEXSBLKF CEXSVC01 CEXTECL CEXTECL1
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI25971
UP15/03/19 P F503
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0"}]
Document Information
Modified date:
22 October 2020