A fix is available
APAR status
Closed as program error.
Error description
CHANGE IOHSECA TO CREATE THE SAME INCORRECT LENGTH FIELD FOR AN AGN ENTRY THAT IMS CREATES. SINCE THIS LENGTH FIELD IS NOT USED BY IMS, THE VALUE IN THE FIELD IS MEANINGLESS. CORRECT ERROR IN RLD COUNT IN LOAD MODULE CONTROL RECORDS WHEN LARGE AGN MATRIX MODULES ARE CREATED.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL IMS HIGH PERFORMANCE SYSGEN USERS. * **************************************************************** * PROBLEM DESCRIPTION: Compare Utility IOHCOMP reports that * * large AGN Security modules are * * different when compared to IMS * * generated AGN Security modules. * **************************************************************** * RECOMMENDATION: * **************************************************************** Compare Utility IOHCOMP reports that large AGN Security modules are different when compared to IMS generated AGN Security modules. Also, receive warning message CSV300I when loading large AGN Security modules from the Matrix library.
Problem conclusion
Change IOHSECA to create the same incorrect length for an AGN entry that IMS creates. Since this length field is not used by IMS, the value in the field is meaningless. Correct error in RLD count in load module control records when large AGN Matrix modules are created.
Temporary fix
Comments
APAR Information
APAR number
PK13878
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-10-21
Closed date
2005-10-26
Last modified date
2005-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK08502
Modules/Macros
IOHLMOD IOHSECA
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R110 PSY UK08502
UP05/10/28 P F510
Fix is available