IBM Support

When saving reports to a file system getting intermittent error: CNC-DS-0025 Cannot write the report output to the file system

Troubleshooting


Problem

We are getting the errors below while trying to save reports to the file system in Cognos Analytics. We have two dispatcher servers in this environment.  This happens intermittently.  We have full access to the path where it says ‘Access Denied’.
60 % of the time reports run successfully and save the output to the file system.   40% of the time we get the errors below.
CNC-DS-0025 Cannot write the report output to the file system: \\AAAAAA\BBB\Reports\Saved_Reports....(Access is denied). RSV-DST-0014 Unable to deliver the output of the report.

Cause

For dispatcher 1, the account logged in for the Cognos service is the domain service account, but for Dispatcher 2, it has 'Local System' as the account.

Resolving The Problem

 Change the dispatcher 2 Cognos service to use the same domain account that is being used for the dispatcher 1 service.  Also "manual" startup for the service is best.  "Automatic" can cause issues because after a reboot of the server, there may be resource contention causing it to fail to start.  
Ensure that the the user starting the Cognos service has full permissions on the Share.   Also ensure that the share is in the same domain as the Cognos server.
For more detailed information about saving reports to a file location review this technote. 
How to Save Report Outputs to a File Location on a Per Report Basis:
https://www.ibm.com/support/pages/how-save-report-outputs-file-location-report-basis

Document Location

Worldwide

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTSF6","label":"IBM Cognos Analytics"},"ARM Category":[{"code":"a8m50000000Cl3yAAC","label":"Installation and Configuration"}],"ARM Case Number":"","Platform":[{"code":"PF033","label":"Windows"}],"Version":"All Version(s)"}]