A fix is available
APAR status
Closed as program error.
Error description
When using remote STC to process /DBR commands, CCF returns rc=0 and msgs CCF0380I/CCF0488I even if data base is still allocated.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS CCF. * **************************************************************** * PROBLEM DESCRIPTION: When using remote STC to process /DBR * * commands, CCF returns rc=0 and msgs * * CCF0380I/CCF0488I even if data base * * is still allocated. * **************************************************************** * RECOMMENDATION: * **************************************************************** This error occurred because the CCF remote STC was only verifying the database was in a stopped state after the /DBR command.
Problem conclusion
With this fix, CCF will now verify the database is also deallocated from IMS before returning the CCF0380I or CCF0488I messages.
Temporary fix
Comments
APAR Information
APAR number
PK11665
Reported component name
IMS COMMAND CTL
Reported component ID
5655F4000
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-09-09
Closed date
2005-11-29
Last modified date
2005-12-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK09562
Modules/Macros
CCFDB510 CCFDB610 CCFDB710 CCFDB810 CCFDB910
Fix information
Fixed component name
IMS COMMAND CTL
Fixed component ID
5655F4000
Applicable component levels
R110 PSY UK09562
UP05/11/30 P F511
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.