A fix is available
APAR status
Closed as program error.
Error description
BTS Playback puts incorrect number on SPA-ONLY 03 RECORDS EXCLUDED FROM TRXOUT and doesn't put the MFS screen about 03 records.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: BTS V3 Users with Playback * **************************************************************** * PROBLEM DESCRIPTION: BTS Playback shows an incorrect number * * on SPA-ONLY 03 RECORDS EXCLUDED FROM * * TRXOUT and doesn't create the MFS scree * * about 03 records. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** BTS Playback (BTSALOG0) shows an incorrect number on SPA-ONLY 03 RECORDS EXCLUDED FROM TRXOUT in "BTSALOG0 SUMMARY". The succeeding BTS step doesn't create any MFS screens about 03 records. BTSALOG0 counted up 03 records SPA-data with the message as SPA-ONLY 03 records and didn't put the message into TRXOUT. BTSALOG0 should not count up 03 records SPA-data with the message as SPA-ONLY 03 records and should put the message into TRXOUT, As the result, BTS can put the message on the MFS output screens.
Problem conclusion
BTSALQR0 is modified to judge SPA-ONLY 03 records. BTSALQP0 is modified not to count up 03 records SPA-data with message as SPA-ONLY 03 records and to put the 03 message into TRXOUT.
Temporary fix
Comments
APAR Information
APAR number
PQ90257
Reported component name
IMS BTS
Reported component ID
5655A1400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-06-16
Closed date
2004-06-22
Last modified date
2004-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ89824
Modules/Macros
BTSALQP0 BTSALQR0
Fix information
Fixed component name
IMS BTS
Fixed component ID
5655A1400
Applicable component levels
R310 PSY UQ89824
UP04/06/23 P F406
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY2","label":"IMS Batch Terminal Simulator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: