IBM Support

PH30487: MISSING INSTRUCTION TYPE REPLACING BY IMS_CALL IN THE IMS DB ANALYSIS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Statement type is set to IMS_CALL instead of using correct
    type defined in the source if the lenght of this variables are 3
    characters and not 4 like in the definition PIC X(4)
    
    01  GU-XXXX            PIC X(4)      VALUE 'GU '.
    01  GN-XXXX            PIC X(4)      VALUE 'GN '.
    

Local fix

  • n/a
    

Problem summary

  • It was a defect, in our code we only check for 'GN', 'GU', 'GN
    'and 'GU  ' (with 2 blanks).
    

Problem conclusion

  • The fix will be available in 5.1.0.9 version.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30487

  • Reported component name

    AD MAINFRAME

  • Reported component ID

    5737B1610

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-13

  • Closed date

    2021-01-11

  • Last modified date

    2021-01-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AD MAINFRAME

  • Fixed component ID

    5737B1610

Applicable component levels

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRR9Q","label":"IBM Application Discovery for IBM Z"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510"}]

Document Information

Modified date:
12 January 2021