Error description
This APAR provides following items: - STACK capability for secondary IC - LBI tape support for Recovery function
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy * * for z/OS version 3 users (FMID=H1J0310) * **************************************************************** * PROBLEM DESCRIPTION: This APAR improves HPIC stack option: * * - Defferent ddname of secondary IC to * * the same ddname of primary IC can be * * used in the Image Copy function. * * - The specification order of ddname can * * be changed in the Create Image Copy * * function. * * * * This APAR also fixes following * * problems: * * - In the Create Image Copy function, * * and the Recovery function, HPIC * * abends S013 ( ABEND013 ) when the * * record format of input image copy * * data set is LBI. * * - In the Create Image Copy function, * * HPIC abends S0C1 ( ABEND0C1 ) when * * ICERPRT DD is not specified in the * * JCL. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR provides following enhancements for HPIC stack option: - Different ddname of secondary IC to the same ddname of primary IC can be used in the Image Copy function. - The specification order of ddname can be changed in the Create Image Copy function. This APAR fixes following problem: - In the Create Image Copy function, and the Recovery function, HPIC abends S013 ( ABEND013 ) when the record format of input image copy data set is LBI. - In the Create Image Copy function, HPIC abends S0C1 ( ABEND0C1 ) when ICERPRT DD is not specified in the JCL.
Problem conclusion
Temporary fix
Comments
The module FABJICDD has been modified to remove the logic that checks the ddname of secondary IC, and specification order of ddname for the stack output data set. The module FABJRDB9, FABJCRC1 have been modified to bypass the logic that issues BUILDRCD macro for LBI format data set of the input image copy data set. The module FABJCRC0, FABJCRC1 have been modified to bypass the logic that calls FABJRPT0 when ICERPRT DD is not specified in the JCL. The module FABJMSGC has been modified to collect the message text of FABJ3932E ( MSGFABJ3932E ). << Documentation Change >> IMS High Performance Image Copy for z/OS Version 3 Release 1s User's Guide SC18-7617-00 ( SC18761700 ) should be changed as follows: ============================================================== 2.0 Operating Instructions 2.2 JCL Requirements 2.2.1 FABJMAIN JCL +-----------------------------------------------------------+ | Table 6. DD statements for the Create Image Copy function | | of the FABJMAIN JCL | +-----------+---------+-----------+-------------------------+ | DDNAME | Use | Format | Required or Optional | +-----------+---------+-----------+-------------------------+ ||ICERPRT |Output |LRECL=133 |Optional | +-----------+---------+-----------+-------------------------+ |ICEDLIST |Output |LRECL=133 |Optional | +-----------+---------+-----------+-------------------------+ 2.0 Operating Instructions 2.2 JCL Requirements 2.2.1 FABJMAIN JCL 2.2.1.3 Function-Unique DD Statement for HPIC Create Image Copy Function ICERPRT DD |This statement specifies the optional output message data set. This data set contains the Create Image Copy report. It can reside on a tape, a direct-access volume, or a printer, or it can be routed through the output stream (SYSOUT).
APAR Information
APAR number
PQ97677
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-11-26
Closed date
2004-12-08
Last modified date
2005-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ95850
Modules/Macros
FABJCRC0 FABJCRC1 FABJICDD FABJMSGC FABJRDB9
SC18761700 |
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R310 PSY UQ95850
UP04/12/09 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS HP Image Copy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
14 December 2020