A fix is available
APAR status
Closed as program error.
Error description
Autonomics Director calculates DB_HOURS_SINCE_LASTIC incorrectly incorrectly. As the result, the following exception occurs: IRO4930I Hours since the last IC has reached or exceeded a threshold for the following data sets or area of xxxxxxxx
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS * * Version 1 Release 6 (FMID: HAHN160) who use * * the Autonomics Director. * **************************************************************** * PROBLEM DESCRIPTION: The value of DB_HOURS_SINCE_LASTIC is * * not calculated correctly after image * * copy job run. As the reuslt of this * * error, DB_HOURS_SINCE_LASTIC exception * * is occurred. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR and * * restart Autonomics Director server. * **************************************************************** The module HKTSCTP1 calculates DB_HOURS_SINCE_LASTIC with current time and last image copy time. However, the current time is not current. As the result, the number of hours since the last image copy was taken is incorrect.
Problem conclusion
The module HKTSCTP1 has been modified to calculate the value of DB_HOURS_SINCE_LASTIC correctly.
Temporary fix
Comments
APAR Information
APAR number
PH19482
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-20
Closed date
2019-12-03
Last modified date
2020-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66735
Modules/Macros
HKTSCTP1
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI66735
UP19/12/04 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]
Document Information
Modified date: