A fix is available
APAR status
Closed as program error.
Error description
ERROR DESCRIPTION:Ø Routing rule refresh can result in a processing error, depending on the state of storage obtained during the refresh process. This error results in a message being issued: FUN1007E Processing error 04390314. INFO=FNCM/CONSOLE and the refresh process is terminated.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.4 * **************************************************************** * PROBLEM DESCRIPTION: OTMA routing rule refresh * * error - FUN1007E Processing error * * 04390314 * **************************************************************** * RECOMMENDATION: * **************************************************************** Routing rule refresh can result in a processing error, depending on the state of storage obtained during the refresh process. This error results in a message being issued: FUN1007E Processing error 04390314. INFO=FNCM/CONSOLE and the refresh process is terminated.
Problem conclusion
Replace a reference to a new, uninitialized Routing Rule area with the intended Routing Rule reference
Temporary fix
Comments
APAR Information
APAR number
PI91767
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-20
Closed date
2018-01-25
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CEXFUNCM
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI53463
UP18/01/30 P F801
Fix is available