PQ59696: S0C1 ABEND WHEN APPLICATION ONLY TAKES ONE CHKP AND GETS A NON- ZERO RETURN CODE. WTOR DETERMINES UNEXPECTED EXTENDED RESTART.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Issue #1: S0C1 abend is occurring if an application
    terminates itself with a non-zero return code after
    making only one  successful CHKP call.
     
    Issue #2: An option is needed to force a WTOR
    allowing an operator to allow or disallow an unexpected
    extended restart  from occurring.
     
    Recommendation: Install the recommended  maintenance.
    This maintenance is being held so you will be aware
    of documentation changes to the Program Restart
    user guide:
     
    - Under the section specifying Inclusion Data Set
      Options, add the following text:
     
    AUTOWTOR=YES
    Specifying this option will cause  Program Restart to
    issue a WTOR if an automatic extended restart can be
    performed.  Message IRT014A is displayed requiring
    an operator to reply  YES, NO or ABEND.  Replying
    'YES' will have the affect of allowing Program  Restart
    to automatically support the extended restart.  Replying
    'NO' will  have the affect of  ignoring the extended restart.
    Replying 'ABEND'  will  cause the job to terminate with
    a user abend code of U3627.
    - Add the following abend code:
     
    3627
     
    Explanation: AUTOWTOR=YES was specified in the
    Inclusion Options Data Set,  an automatic extended restart
    was possible, and the operator replied ABEND to  the
    IRT014A WTOR when the job was resubmitted.
    System Action: The job step  abnormally terminates with
    a U3627 completion code.
    User Response: See  message IRT014A for more details.
     
    - Change the following message:
     
    IRT014A REPLY WITH AUTOXRST OPTION: "YES",
     "NO" OR "ABEND"
     
    Explanation:  Program Restart has identified the running job as
               possibly requiring an extended restart. This WTOR is
             displayed because the  installation coded AUTOWTOR=YES
             in the PRF Inclusion Options Data Set.
     
    System Action: The job waits until an operator replies YES,
    NO or  ABEND.  If the reply is YES, the job will continue
    with an automatic  extended restart.  If the reply is NO, the
    job will continue, but no  extended restart will take place.
    If the reply is ABEND, the job will  abend U3627.
    rogrammer Action: None
     
    Comments:
     
    The following modules and/or macros are affected by this PTF:
     
    Modules:
      IRTPRE00
      IRTAOPT0
      IRTXSC05
      IRTXSC06
      IRTXSC07
      IRTXSC08
    

Local fix

  • 
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: ALL USERS OF IMS PROGRAM RESTART FACILITY.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: THIS APAR ADDRESSES THE FOLLOWING       *
    *                      ISSUES:                                 *
    *                                                              *
    *                      ISSUE #1: S0C1 ABEND IS OCCURRING IF    *
    *                      AN APPLICATION TERMINATES ITSELF WITH   *
    *                      A NON-ZERO RETURN CODE AFTER MAKING     *
    *                      ONLY ONE SUCCESSFUL CHKP CALL.          *
    *                                                              *
    *                      ISSUE #2: AN OPTION IS NEEDED TO FORCE  *
    *                      A WTOR ALLOWING AN OPERATOR TO ALLOW    *
    *                      OR DISALLOW AN UNEXPECTED EXTENDED      *
    *                      RESTART FROM OCCURRING.                 *
    *                                                              *
    *                      ISSUE #3: AUTOXRST=NO OPTION IS NOT     *
    *                      BEING SET PROPERLY IF THE CUSTOMER      *
    *                      USES THE IRT#CPID EXCEPTION CKPTID      *
    *                      TABLE.                                  *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    *                 INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    THIS APAR IS ADDRESSING THE FOLLOWING ISSUES:
    
    ISSUE #1:  S0C1 ABEND IS OCCURRING IF AN APPLICATION
    TERMINATES ITSELF WITH A NON-ZERO RETURN CODE AFTER
    MAKING ONLY ONE SUCCESSFUL CHKP CALL.
    
    ISSUE #2:  AN OPTION IS NEEDED TO FORCE A WTOR ALLOWING
    AN OPERATOR TO ALLOW OR DISALLOW AN UNEXPECTED EXTENDED
    RESTART FROM OCCURRING.
    
    ISSUE #3:  AUTOXRST=NO OPTION IS NOT BEING SET PROPERLY
    IF THE CUSTOMER USES THE IRT#CPID EXCEPTION CKPTID TABLE.
    

Problem conclusion

  • THE CODE HAS BEEN MODIFIED TO ADDRESS ALL OF
    THE ISSUES DESCRIBED IN THIS APAR.
    

Temporary fix

  • 
    

Comments

  • 
    

APAR Information

  • APAR number

    PQ59696

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2002-04-02

  • Closed date

    2002-05-28

  • Last modified date

    2002-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    H23D210J IRTAOPT0 IRTPRE00 IRTXSC05 IRTXSC06
    IRTXSC07 IRTXSC08
    

Publications Referenced
SC27091000

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R210 PSY UQ66680

       UP02/05/30 P F205

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
24 January 2022