Error description
Customers with Data Collectors on Windows could experience problems adding storage devices if the resulting path name starts with a Windows reserved words. If the path name (derived from the user adding the device and the device name) starts with any of the Windows reserved words, the Add device operation will fail, and the device cannot be monitored. Windows folders cannot have their name start with any of these reserved words: CON, PRN, AUX, NUL, COM1, COM2, COM3, COM4, COM5, COM6, COM7, COM8, COM9, LPT1, LPT2, LPT3, LPT4, LPT5, LPT6, LPT7, LPT8, LPT9