Fixes are available
APAR status
Closed as program error.
Error description
DS3500 firmware level is not displayed due to issues in the mappper. The column "code_level" in table T_res_storage_subsystem is empty.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users monitoring DS3500 storage * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0012 - target November 2016 Fixed in IBM Spectrum Control 5.2.12. http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT16105
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
52A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-13
Closed date
2016-08-16
Last modified date
2016-08-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DISK
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
R52A PSY
UP
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52A"}]