IBM Support

VM66420: SET EDEVICE OPTIONAL LUN SPECIFICATION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This support allows the LUN operand to be optional.
    The LUN operand is optional on the SET EDEVICE command and the
    EDEVICE system configuration statement after the first path has
    been established.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of SET EDEVICE and EDEVICE system  *
    *                 configuration statement                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    This support will allow the LUN operand to be optional on the
    SET EDEVICE command and the EDEVICE system configuration
    statement after the first path has been established.
    

Problem conclusion

Temporary fix

Comments

  • Code has been updated to add support for specification of the
    LUN optional after the first path has been established.  The
    following documentation changes have been made.
    
    SC24-6268-06 z/VM: CP Commands and Utilities Reference
    SET EDEVICE command
    The following note has been added regarding the LUN operand
    
    The LUN operand is required when you define the first path to
    an EDEVICE.  For subsequent paths, the LUN operand is optional.
    If you specify the LUN operand, the value must match the LUN on
    the first path.
    
    Response 8 has also been added
    
    To define an emulated device 5004 for a 2145 device with two
    paths where LUN is optional on the second path, enter the
    following:
    
    set edev 5004 type fba attr 2145
      fcp_dev 800 wwpn 200400A0B80BA687 lun 0002000000000000
      fcp_dev 801 wwpn 200400A0B80BA688
    EDEV 5004 was created.
    Ready;
    
    GC24-6270-06 z/VM: CP Messages and Codes
    HCP8703E
    A third variation of message HCP88703E has been added.
    
    - Variation 3 The LUN lun specified does not match the LUN that
    is already associated with EDEV rdev.
    
    Explanation:
    
    A path was specified with the SET EDEVICE command or EDEVICE
    system configuration statement and the LUN does not match the
    LUN that is already associated with the EDEVICE.
    
    System action:
    
    The path is not added to the emulated device definition. System
    operation continues.
    
    User response:
    
    Issue a CP QUERY EDEVICE command to determine the LUN associated
    with the EDEVICE. Issue a CP SET EDEVICE command with the
    correct LUN.  If the EDEVICE was incorrectly defined in the
    system configuration file, update the LUN in the EDEVICE
    system configuration statement.
    ×**** PE21/08/02 FIX IN ERROR. SEE APAR VM66555  FOR DESCRIPTION
    

APAR Information

  • APAR number

    VM66420

  • Reported component name

    VM CP

  • Reported component ID

    568411202

  • Reported release

    720

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2020-07-27

  • Closed date

    2020-12-04

  • Last modified date

    2021-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM35785

Modules/Macros

  • EDEVICE  HCPEDEV  HCPMES   HCPMESB  HCPMXRBK HCPSDU   HCPSZM
    HCPSZP   HCPZSR   HCP8703E
    

Publications Referenced
GC24627006SC24626806   

Fix information

  • Fixed component name

    VM CP

  • Fixed component ID

    568411202

Applicable component levels

  • R720 PSY UM35785

       UP20/12/08 P 2101  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"720","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]

Document Information

Modified date:
15 September 2021