Error description
Facing several assertions when issuing the following type of query: Running the following query I was able to reproduce the issue: SELECT rowid, "xyz" FROM (SELECT COUNT(*) "xyz" FROM "stores":"informix"."table_a" "table_xyz") abc WHERE "xyz">(0) The stack signature shows: oninit :: evalcols oninit :: getrow oninit :: fetchrow oninit :: exfetch oninit :: sql_nfetch oninit :: sq_nfetch oninit :: sqmain oninit :: listen_verify oninit :: spawn_thread oninit :: th_init_initgls oninit :: startup
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC5. * **************************************************************** * PROBLEM DESCRIPTION: * * Facing several assertions when issuing the following type of * * query: * * * * Running the following query reproduces the issue: * * * * SELECT rowid, "xyz" FROM (SELECT COUNT(*) "xyz" FROM * * "stores":"informix"."table_a" "table_xyz") abc WHERE * * "xyz">(0) * * * * The stack signature shows: * * oninit :: evalcols * * oninit :: getrow * * oninit :: fetchrow * * oninit :: exfetch * * oninit :: sql_nfetch * * oninit :: sq_nfetch * * oninit :: sqmain * * oninit :: listen_verify * * oninit :: spawn_thread * * oninit :: th_init_initgls * * oninit :: startup * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 (when available) or * * 14.10.xC5. * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC15 and 14.10.xC5.
Temporary fix
Comments
APAR Information
APAR number
IT33874
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-11
Closed date
2021-01-25
Last modified date
2021-01-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10"}]
Document Information
Modified date:
26 January 2021