Error description
Case TS003576035 Describes problem where IO_COUNT is NULL in table MVS_WORKLOAD2_H. Values are coming across all zeros.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: TDSz/IZDS/IZPCA users of the z/OS System * * (MVS) - 3 Workload Statistics. * **************************************************************** * PROBLEM DESCRIPTION: Getting message DRL0337W when trying to * * collect log in z/OS System (MVS) * * component, subcomponent 3 Workload * * Statistics. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The value for field R723MIOC of record SMF_072_3 is 0 and this creates an error when the value of column IO_COUNT is computed in the table MVS_WORKLOAD2_H.
Problem conclusion
Update the code to check if the value for field R723MIOC of record SMF_072_3 is 0 and set column IO_COUNT to 0 if it is. Otherwise do the existing computation. Did the same check for fields R723MADJ and R723MCPU to compute for columns CAPACITY_CPU_SU and SU_UNWEIGHT_CPU respectively.
Temporary fix
Comments
APAR Information
APAR number
PH25202
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
802
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-08
Closed date
2020-07-20
Last modified date
2020-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI70634 UI70635 UI70636 UI70637 UI70638
Modules/Macros
DRLTMVW2
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
R80A PSY UI70635
UP20/07/21 P F007
R8A0 PSY UI70634
UP20/07/21 P F007
R8A9 PSY UI70636
UP20/07/21 P F007
R9A0 PSY UI70637
UP20/07/21 P F007
RCA0 PSY UI70638
UP20/07/21 P F007
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"802","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: