A fix is available
APAR status
Closed as program error.
Error description
Data-item marked as unreferenced despite of usage with LENGTH OF special register using RULES(NOUNRS)
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 who compile * * with RULES(NOUNREFSOURCE) and have a * * program with LENGTH OF with a LINKAGE * * SECTION operand that is otherwise not * * referenced in the program. * **************************************************************** * PROBLEM DESCRIPTION: The compiler reports that the LENGTH OF * * operand is unreferenced, but it IS * * referenced by the LENGTH OF special * * register. * **************************************************************** * RECOMMENDATION: Apply the provided PTF and recompile. * **************************************************************** The compiler was not marking LENGTH OF operands as referenced so the RULES(NOUNREFSOURCE) reported the LENGTH OF operand as unreferenced.
Problem conclusion
A special flag for LENGTH OF was added to show that it was referenced by LENGTH OF, but storage does not need to be available for the LINKAGE SECTION operand of LENGTH OF.
Temporary fix
Comments
APAR Information
APAR number
PH27297
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-13
Closed date
2020-08-18
Last modified date
2020-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8CICS IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI71111
UP20/08/29 P F008
R621 PSY UI71112
UP20/08/29 P F008
R622 PSY UI71113
UP20/08/29 P F008
R62H PSY UI71114
UP20/08/29 P F008
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023